Plugin name 'sidebar.BROKEN' is not a valid plugin name, only the characters a-z and 0-9 are allowed. Maybe the plugin has been installed in the wrong directory?

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
manual_egk-lw20lt00 [2024/03/12 11:51] – [2.5 Battery] supportadminmanual_egk-lw20lt00 [2025/02/28 12:35] (current) – [10 Declaration of conformity] supportadmin
Line 1: Line 1:
 =====   ===== =====   =====
  
-{{  :enginko_logo_colori_exe.jpg?nolink&200  }}+{{  :enginko_logo_colori_exe.jpg?nolink&200  |Stampa}}
  
 ===== EGK-LW20LT00 Operating Manual ===== ===== EGK-LW20LT00 Operating Manual =====
Line 10: Line 10:
  
   * Do not dismantle or modify in any way.   * Do not dismantle or modify in any way.
-  * The device is not intended to be used as a reference sensor, and enginko Srl will not be held liable for any damage which may result from inaccurate readings.+  * The device is not intended to be used as a reference sensor, and Angel4Future Srl will not be held liable for any damage which may result from inaccurate readings.
   * Avoid mechanical stress   * Avoid mechanical stress
   * Do not use any detergent or alcohol to clean the device.   * Do not use any detergent or alcohol to clean the device.
Line 36: Line 36:
  
 {{  :wiki:manual_egk-lw22twp00:egk-lw22twp10.png?300x140  }} {{  :wiki:manual_egk-lw22twp00:egk-lw22twp10.png?300x140  }}
- 
  
 ===== 2. Overview ===== ===== 2. Overview =====
Line 73: Line 72:
 ==== 2.2 Installation ==== ==== 2.2 Installation ====
  
-__To ensure correct operation and reliable and consistent level measurements, install the EGK-LW20LT00 sensor in front of the target whose distance need to be measured and away from direct sunlight and rain.__ . Screws are provided. Mounting could be vertical or horizontal, depending on the application.+__To ensure correct operation and reliable and consistent level measurements, install the EGK-LW20LT00 sensor in front of the target whose distance need to be measured and away from direct sunlight and rain.__  . Screws are provided. Mounting could be vertical or horizontal, depending on the application.
  
 The device must be placed where the LoRaWAN® signal coverage is good (SF = 7 optimal, SF = 12 weak). The device must be placed where the LoRaWAN® signal coverage is good (SF = 7 optimal, SF = 12 weak).
Line 82: Line 81:
  
 __**Custom brackets available on request.**__ __**Custom brackets available on request.**__
 +
 === 2.2.1 Wall mount === === 2.2.1 Wall mount ===
  
Line 94: Line 94:
 For installation on poles, pillars or posts use the included bracket and fasteners: For installation on poles, pillars or posts use the included bracket and fasteners:
  
-{{  :wiki:manual_egk-lw20l00:pole_mount_1.jpg  |pole_mount_1.jpg}}=== 2.2.3 LoRa Tool ===+{{  :wiki:manual_egk-lw20l00:pole_mount_1.jpg  |pole_mount_1.jpg}} 
 + 
 +=== 2.2.3 LoRa Tool ===
  
 To deploy the sensor, download the latest __**LoRa Tool**__  Android App to setup LoRaWAN® credentials and other preferences : To deploy the sensor, download the latest __**LoRa Tool**__  Android App to setup LoRaWAN® credentials and other preferences :
Line 113: Line 115:
  
 {{  :wiki:manual_egk-lw20l00:bt_read.jpg?400  |bt_read.jpg}} {{  :wiki:manual_egk-lw20l00:bt_read.jpg?400  |bt_read.jpg}}
- 
  
 ==== 2.3 Power ON/OFF ==== ==== 2.3 Power ON/OFF ====
Line 121: Line 122:
 To power on the sensor: lay the magnet at the bottom of the provided tool into the area shown in the figure: To power on the sensor: lay the magnet at the bottom of the provided tool into the area shown in the figure:
  
-{{  :wiki:manual_egk-lw20l00:on_mag.jpg  }}+{{  :wiki:manual_egk-lw20l00:on_mag.jpg  |on_mag.jpg}}
  
 Successful power on is signaled by the flashing of the 2 LEDs. Successful power on is signaled by the flashing of the 2 LEDs.
Line 127: Line 128:
 In case of long period of inactivity, if necessary, is possible to shut-off again the sensor to prevent battery consumption, via downlink or with LoRa Tool App: In case of long period of inactivity, if necessary, is possible to shut-off again the sensor to prevent battery consumption, via downlink or with LoRa Tool App:
  
-{{  :wiki:manual_egk-lw20l00:bt_off.jpg?400  }}+{{  :wiki:manual_egk-lw20l00:bt_off.jpg?400  |bt_off.jpg}}
  
 ==== 2.4 System leds ==== ==== 2.4 System leds ====
  
-{{  :wiki:manual_egk-lw20l00:egk-lw20l00_led.jpg?400  }}+{{  :wiki:manual_egk-lw20l00:egk-lw20l00_led.jpg?400  |egk-lw20l00_led.jpg}}
  
-|LoRaWAN® not configured|  {{:wiki:manual_mcf-lw12co2e:gfrf_rev0.jpg?80}}  |Slow flashing| +|LoRaWAN® not configured|  {{:wiki:manual_mcf-lw12co2e:gfrf_rev0.jpg?80|gfrf_rev0.jpg}}  |Slow flashing| 
-|Joining|  {{:wiki:manual_mcf-lw12co2e:gf_ev0.jpg?40}}  |Quick flashing| +|Joining|  {{:wiki:manual_mcf-lw12co2e:gf_ev0.jpg?40|gf_ev0.jpg}}  |Quick flashing| 
-|Sending|  {{:wiki:manual_mcf-lw12co2e:gf_ev0.jpg?40}}  |Quick flashing|+|Sending|  {{:wiki:manual_mcf-lw12co2e:gf_ev0.jpg?40|gf_ev0.jpg}}  |Quick flashing|
  
 ==== 2.5 Battery ==== ==== 2.5 Battery ====
Line 146: Line 147:
 |EGK-1S2PCR|  4800mAh battery pack  | |EGK-1S2PCR|  4800mAh battery pack  |
  
-__Replacement battery only available from enginko.__+__Replacement battery only available from Angel4Future.__
  
 This is the estimated battery life (in **years**) in the worst conditions: This is the estimated battery life (in **years**) in the worst conditions:
Line 176: Line 177:
 {{  :wiki:manual_mcf-lw12terwp:batt_res.jpg?400  |batt_res.jpg}} {{  :wiki:manual_mcf-lw12terwp:batt_res.jpg?400  |batt_res.jpg}}
  
-To perform the operation, you need a unique reset code that must be requested to enginko (please provide the DevEUI of the sensor when you ask for that code):+To perform the operation, you need a unique reset code that must be requested to Angel4Future (please provide the DevEUI of the sensor when you ask for that code):
  
 {{  :wiki:manual_mcf-lw12co2e:battery_res_0.jpg?400  |battery_res_0.jpg}} {{  :wiki:manual_mcf-lw12co2e:battery_res_0.jpg?400  |battery_res_0.jpg}}
  
 At the end of the procedure the battery level displays 100%. At the end of the procedure the battery level displays 100%.
- 
  
 ==== 2.6 Firmware update ==== ==== 2.6 Firmware update ====
Line 187: Line 187:
 Download the latest firmwares available on the smartphone: Download the latest firmwares available on the smartphone:
  
-{{  :wiki:manual_egk-lw20w00:update_firmwares.jpg?direct&400  }}+{{  :wiki:manual_egk-lw20w00:update_firmwares.jpg?direct&400  |update_firmwares.jpg}}
  
 Upload it with LoraTool App: Upload it with LoraTool App:
  
-{{  :wiki:manual_egk-lw20l00:bt_fw.jpg?400  }}+{{  :wiki:manual_egk-lw20l00:bt_fw.jpg?400  |bt_fw.jpg}}
  
 ===== 3. Measures ===== ===== 3. Measures =====
Line 197: Line 197:
 On each reading of the sensor by LoraTool, the measured distance is shown on the main page: On each reading of the sensor by LoraTool, the measured distance is shown on the main page:
  
-{{  :wiki:manual_egk-lw20l00:sc2_dist.jpg?400  }}+{{  :wiki:manual_egk-lw20l00:sc2_dist.jpg?400  |sc2_dist.jpg}}
  
 Once provisioned on a LoRaWAN® network, the device sends the distance & timestamp to the server via uplink. Once provisioned on a LoRaWAN® network, the device sends the distance & timestamp to the server via uplink.
Line 213: Line 213:
 Starting point of the measurement (in mm from "REFERENCE" point). Starting point of the measurement (in mm from "REFERENCE" point).
  
-Values can be set from 140 to 1360:+Values can be set from 350 to 7000:
  
 {{  :wiki:manual_egk-lw20l00:start_1.jpg?400  |start_1.jpg}} {{  :wiki:manual_egk-lw20l00:start_1.jpg?400  |start_1.jpg}}
Line 221: Line 221:
 A target within the "Start [mm]" distance will result at a “Start” distance. A target within the "Start [mm]" distance will result at a “Start” distance.
  
-The "Start [mm]" value is also related to other level parameters. Contact enginko in case of assistance.+The "Start [mm]" value is also related to other level parameters. Contact Angel4Future in case of assistance.
  
 === 3.1.2 End [mm] === === 3.1.2 End [mm] ===
Line 285: Line 285:
 ==== 3.2 Environmental ==== ==== 3.2 Environmental ====
  
-{{  :wiki:manual_egk-lw22twp00:twp00_app_data1.jpg?400  }}+{{  :wiki:manual_egk-lw22twp00:twp00_app_data1.jpg?400  |twp00_app_data1.jpg}}
  
 === 3.2.1 Temperature === === 3.2.1 Temperature ===
Line 295: Line 295:
 When the sensor is not installed at the sea level, the reading of barometric pressures at other elevations must be compensated. Set the right altitude value with LoRa Tool app: When the sensor is not installed at the sea level, the reading of barometric pressures at other elevations must be compensated. Set the right altitude value with LoRa Tool app:
  
-{{  :wiki:manual_egk-lw22twp00:twp00_app_set1.jpg?400  }}+{{  :wiki:manual_egk-lw22twp00:twp00_app_set1.jpg?400  |twp00_app_set1.jpg}}
  
 Value can be from -300 to 3000 meters. Value can be from -300 to 3000 meters.
Line 307: Line 307:
 The sensor is compliant with LoRaWAN® specification 1.0.2. The sensor is compliant with LoRaWAN® specification 1.0.2.
  
-{{  :wiki:manual_mcf-lw12co2e:activation2_0.jpg?400  }}+{{  :wiki:manual_mcf-lw12co2e:activation2_0.jpg?400  |activation2_0.jpg}}
  
 ==== 4.1 Activation ==== ==== 4.1 Activation ====
Line 318: Line 318:
   - **OTAA ENGINKO**: Over the air activation, fixed keys: JoinEUI = 904e915000000001, AppKey on request;   - **OTAA ENGINKO**: Over the air activation, fixed keys: JoinEUI = 904e915000000001, AppKey on request;
   - **ABP**: requires writing to the device of NwkSkey, AppSkey, DevAddr.   - **ABP**: requires writing to the device of NwkSkey, AppSkey, DevAddr.
-{{  :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400  }}+{{  :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400  |activation1_0.jpg}}
  
-The device exits factory activated with **NONE**  mode. On request devices can be shipped already activated.+The device exits factory activated with **OTAA ENGINKO**  mode. On request devices can be shipped already activated.
  
 Note: in **OTAA**  AppKey is write only, in reading the field will always be empty, even if set. Note: in **OTAA**  AppKey is write only, in reading the field will always be empty, even if set.
Line 338: Line 338:
 ==== 4.2 Other settings ==== ==== 4.2 Other settings ====
  
-**Network settings**:  please keep "Any" settings. Change it only if Objenious network is used (default_ any).+**Network settings**: please keep "Any" settings. Change it only if Objenious network is used (default_ any).
  
-**Network type**:  LoRa syncword can be setted as "private"(0x12) instead "public" (0x34), but __the NS must be setted accordingly__  (default: public).+**Network type**: LoRa syncword can be setted as "private"(0x12) instead "public" (0x34), but __the NS must be setted accordingly__  (default: public).
  
-**Band**:  select the right LoRaWAN ® band settings accodingly to country requirements.+**Band**: select the right LoRaWAN ® band settings accodingly to country requirements.
  
-{{  :wiki:manual_mcf-lw12co2e:activation3_0.jpg?400  }}+{{  :wiki:manual_mcf-lw12co2e:activation3_0.jpg?400  |activation3_0.jpg}}
  
-**DST**:  set to change DST (default: none).+**DST**: set to change DST (default: none).
  
-**No time sync**:  set to disable time synchronization request (default: enabled).+**No time sync**: set to disable time synchronization request (default: enabled).
  
-**UnConfirmed**:  set for unconfirmed uplinks (default: confirmed uplink).+**UnConfirmed**: set for unconfirmed uplinks (default: confirmed uplink).
  
-**Led OFF**:  set to disable the led.+**Led OFF**: set to disable the led.
  
-**Single join/day**:  set for to allow only one join per day (default: multiple join allowed).+**Single join/day**: set for to allow only one join per day (default: multiple join allowed).
  
-**Period**:  time interval between two measures (in minutes).+**Period**: time interval between two measures (in minutes).
  
-**Clock timed**:  set to sincronize the reading with the internal clock.+**Clock timed**: set to sincronize the reading with the internal clock.
  
-**Accelerometer**:  set to enable asynchronous measure in case of shaking (useful for debug).+**Accelerometer**: set to enable asynchronous measure in case of shaking (useful for debug).
  
-{{  :wiki:manual_egk-lw20l00:bt_set1.jpg?400  }}+{{  :wiki:manual_egk-lw20l00:bt_set1.jpg?400  |bt_set1.jpg}}
  
 ===== 5 Passwords ===== ===== 5 Passwords =====
Line 374: Line 374:
 To change the passwords, set the new values with the LoRa Tool App: To change the passwords, set the new values with the LoRa Tool App:
  
-{{  :wiki:manual_mcf-lw12co2e:password1_0.jpg?400  }}+{{  :wiki:manual_mcf-lw12co2e:password1_0.jpg?400  |password1_0.jpg}}
  
 Once the passwords are setted, to gain access from LoRa Tool to the sensor, open the App: Once the passwords are setted, to gain access from LoRa Tool to the sensor, open the App:
  
-{{  :wiki:manual_egk-lw20l00:bt_scan.jpeg?400  }}+{{  :wiki:manual_egk-lw20l00:bt_scan.jpeg?400  |bt_scan.jpeg}}
  
 and set the right values before reading from the device: and set the right values before reading from the device:
  
-{{  :wiki:manual_mcf-lw12co2e:password2_0.jpg?400  }}+{{  :wiki:manual_mcf-lw12co2e:password2_0.jpg?400  |password2_0.jpg}}
  
-To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko (please provide the DevEUI of the sensor when you ask for that code).+To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future (please provide the DevEUI of the sensor when you ask for that code).
  
 ===== 6 Configuration file ===== ===== 6 Configuration file =====
  
-WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in case of multiple devices configuration.+WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in case of multiple devices configuration.
  
-With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to enginko's support if needed.+With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to Angel4Future's support if needed.
  
-{{  :wiki:manual_mcf-lw12co2e:files_rev0.jpg?400  }}+{{  :wiki:manual_mcf-lw12co2e:files_rev0.jpg?400  |files_rev0.jpg}}
  
 ==== 6.1 Multi devices configuration ==== ==== 6.1 Multi devices configuration ====
Line 415: Line 415:
   * Writing the passwords.   * Writing the passwords.
  
-{{  :wiki:manual_mcf-lw12co2e:multiple_rev0.jpg?400  }}+{{  :wiki:manual_mcf-lw12co2e:multiple_rev0.jpg?400  |multiple_rev0.jpg}}
  
-For details on files format please ask to enginko.+For details on files format please ask to Angel4Future.
  
 ===== 7 LoRaWEB Tool ===== ===== 7 LoRaWEB Tool =====
  
-enginko provides, upon free registration, **LoRaWEB**  online tool, where for each sensor it is possible to find documentation, javascript examples for parsing, downlink generator and uplink decoder:+Angel4Future provides free **LoRaWEB**  online tool, where for each sensor it is possible to find documentation, javascript examples for parsing, downlink generator and uplink decoder:
  
 [[https://iot.mcf88.cloud/LoRaWeb/#/configuration|LoRaWEB Tool]] (iot.mcf88.cloud/LoRaWeb) [[https://iot.mcf88.cloud/LoRaWeb/#/configuration|LoRaWEB Tool]] (iot.mcf88.cloud/LoRaWeb)
  
-{{  :wiki:manual_mcf-lw12co2e:lt1_0.jpg?600  }}+{{  :wiki:manual_mcf-lw12co2e:lt1_0.jpg?600  |lt1_0.jpg}}
  
-{{  :wiki:manual_mcf-lw12co2e:lt2_0.jpg?600  }}+{{  :wiki:manual_mcf-lw12co2e:lt2_0.jpg?600  |lt2_0.jpg}}
  
 ===== 8 Payload ===== ===== 8 Payload =====
Line 438: Line 438:
  
 ^Ordering Code  ^Description| ^Ordering Code  ^Description|
-|EGK-LW20LT00|  enginko LoRaWAN® outdoor level and environmental sensor EU863-870| +|EGK-LW20LT00|enginko LoRaWAN® outdoor level and environmental sensor EU863-870| 
-|EGK-LW20LT10|  enginko LoRaWAN® outdoor level and environmental sensor with external antenna EU863-870 |+|EGK-LW20LT10|enginko LoRaWAN® outdoor level and environmental sensor with external antenna EU863-870| 
 ===== 10 Declaration of conformity ===== ===== 10 Declaration of conformity =====
  
-Hereby, enginko Srl declares that EGK-LW20LT00 complies with the essential requirements and other relevant provisions of Directive 2014/53/EU.+Declarations of conformity are available from Angel4Future by sending a request email to sensor@enginko.com.
  
 ===== 11 Contacts ===== ===== 11 Contacts =====
  
-**enginko Srl** \\ Via Roma 3 I-28060 Sozzago (NO) \\ T : +39 0321 15 93 088+**Angel4Future S.r.l.** \\  
 +Via San Sabino 21 70042 MOLA DI BARI (BA, ITALY \\  
 +    +39 080 532 1796 \\  
  
-E : info@enginko.com \\ PEC: enginkosrl@legalmail.it \\ W: enginko.com+    info@angel4future.com  \\  
 +W:     enginko.com \\ 
  
 ---- ----
  
-Document rev. 0+Document rev. 1
  
 ---- ----