Plugin name 'sidebar.BROKEN' is not a valid plugin name, only the characters a-z and 0-9 are allowed. Maybe the plugin has been installed in the wrong directory?

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
manual_egk-lw20w00 [2024/02/14 09:38] – [2.5 Battery] supportadminmanual_egk-lw20w00 [2025/03/25 15:07] (current) – [Table] supportadmin
Line 10: Line 10:
  
   * Do not dismantle or modify in any way.   * Do not dismantle or modify in any way.
-  * The device is not intended to be used as a reference sensor, and enginko Srl will not be held liable for any damage which may result from inaccurate readings.+  * The device is not intended to be used as a reference sensor, and Angel4Future Srl will not be held liable for any damage which may result from inaccurate readings.
   * Avoid mechanical stress   * Avoid mechanical stress
   * Do not use any detergent or alcohol to clean the device.   * Do not use any detergent or alcohol to clean the device.
Line 159: Line 159:
 ^Code  ^Description| ^Code  ^Description|
 |EGK-1S2PCR|  4800mAh battery pack   | |EGK-1S2PCR|  4800mAh battery pack   |
-Replacement battery only available from enginko.+__Replacement battery only available from Angel4Future.__\\
  
 This is the estimated battery life (in **years**) in the worst conditions: This is the estimated battery life (in **years**) in the worst conditions:
Line 192: Line 192:
 {{  :wiki:manual_mcf-lw12terwp:batt_res.jpg?400  }} {{  :wiki:manual_mcf-lw12terwp:batt_res.jpg?400  }}
  
-To perform the operation, you need a unique reset code that must be requested to enginko (please provide the DevEUI of the sensor when you ask for that code):+To perform the operation, you need a unique reset code that must be requested to Angel4Future (please provide the DevEUI of the sensor when you ask for that code):
  
 {{  :wiki:manual_mcf-lw12co2e:battery_res_0.jpg?400  }} {{  :wiki:manual_mcf-lw12co2e:battery_res_0.jpg?400  }}
Line 238: Line 238:
 A target within the "Start [mm]" distance will result at a “Start” distance. A target within the "Start [mm]" distance will result at a “Start” distance.
  
-The "Start [mm]" value is also related to other level parameters. Contact enginko in case of assistance.+The "Start [mm]" value is also related to other level parameters. Contact Angel4Future in case of assistance.
  
 === 3.1.2 End [mm] === === 3.1.2 End [mm] ===
Line 298: Line 298:
 __Default: 2__ __Default: 2__
  
 +==== 3.2 Input ====
 +
 +The input status represents the status of the accelerometer (Input = 1 start of accererometer event start, input = 0 end of accelerometer event). 
  
 ===== 4 LoRaWAN network ===== ===== 4 LoRaWAN network =====
Line 316: Line 319:
 {{  :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400  }} {{  :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400  }}
  
-The device exits factory activated with **NONE**  mode. On request devices can be shipped aleady activated.+The device exits factory activated with **OTAA ENGINKO**  mode. On request devices can be shipped aleady activated.
  
 Note: in **OTAA**  AppKey is write only, in reading the field will always be empty, even if set. Note: in **OTAA**  AppKey is write only, in reading the field will always be empty, even if set.
Line 334: Line 337:
 ==== 4.2 Other settings ==== ==== 4.2 Other settings ====
  
-**Network settings**:  please keep "Any" settings. Change it only if Objenious network is used (default_ any). 
  
-**Network type**:  LoRa syncword can be setted as "private"(0x12) instead "public" (0x34), but __the NS must be setted accordingly__  (default: public).+{{  :wiki:manual_mcf-lw12co2e:activation3_0.jpg?400  |activation3_0.jpg}} 
 + 
 +**Network settings**: please keep "Any" settings. Change it only if Objenious network is used (default_ any). 
 + 
 +**Network type**: LoRa syncword can be setted as "private"(0x12) instead "public" (0x34), but __the NS must be setted accordingly__ (default: public). 
 + 
 +**Band**: select the right LoRaWAN ® band settings accodingly to country requirements. 
 + 
 +{{  :wiki:manual_egk-lw20l00:bt_set1.jpg?400  |bt_set1.jpg}} 
 + 
 +**DST**: set to change DST (default: none).
  
-**Band**:  select the right LoRaWAN ® band settings accodingly to country requirements.+**No time sync**: set to disable time synchronization request (default: enabled).
  
-{{  :wiki:manual_mcf-lw12co2e:activation3_0.jpg?400  }}+**UnConfirmed**set for unconfirmed uplinks (defaultconfirmed uplink).
  
-**DST**:  set to change DST (default: none).+**Led OFF**: set to disable the led.
  
-**No time sync**:  set to disable time synchronization request (default: enabled).+**Single join/day**: set for to allow only one join per day (default: multiple join allowed).
  
-**UnConfirmed**:  set for unconfirmed uplinks (default: confirmed uplink).+**Period**: time interval between two measures (in minutes).
  
-**Led OFF**:  set to disable the led.+**Clock timed**: set to sincronize the reading with the internal clock.
  
-**Single join/day**:  set for to allow only one join per day (default: multiple join allowed).+**Accelerometer**: set to enable asynchronous measure in case of shakingAfter the first accelerometer event, the device will not send any message for 3 minutes after the last accelerometer event:
  
-**Period** time interval between two measures (in minutes).+{{ :wiki:manual_egk-lw20w00:accelerometer.jpg?nolink&800 |}}
  
-**Clock timed**:  set to sincronize the reading with the internal clock. 
  
-**Accelerometer**:  set to enable asynchronous measure in case of shaking (useful for debug). 
  
-{{  :wiki:manual_egk-lw20l00:bt_set1.jpg?400  }} 
  
 ===== 5 Passwords ===== ===== 5 Passwords =====
Line 380: Line 389:
 {{  :wiki:manual_mcf-lw12co2e:password2_0.jpg?400  }} {{  :wiki:manual_mcf-lw12co2e:password2_0.jpg?400  }}
  
-To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko (please provide the DevEUI of the sensor when you ask for that code).+To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future (please provide the DevEUI of the sensor when you ask for that code).
  
 ===== 6 Configuration file ===== ===== 6 Configuration file =====
  
-WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in case of multiple devices configuration.+WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in case of multiple devices configuration.
  
-With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to enginko's support if needed.+With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to Angel4Future's support if needed.
  
 {{  :wiki:manual_mcf-lw12co2e:files_rev0.jpg?400  }} {{  :wiki:manual_mcf-lw12co2e:files_rev0.jpg?400  }}
Line 413: Line 422:
 {{  :wiki:manual_mcf-lw12co2e:multiple_rev0.jpg?400  }} {{  :wiki:manual_mcf-lw12co2e:multiple_rev0.jpg?400  }}
  
-For details on files format please ask to enginko.+For details on files format please ask to Angel4Future.
  
 ===== 7 LoRaWEB Tool ===== ===== 7 LoRaWEB Tool =====
  
-enginko provides, upon free registration, **LoRaWEB**  online tool, where for each sensor it is possible to find documentation, javascript examples for parsing, downlink generator and uplink decoder:+Angel4Future provides free **LoRaWEB**  online tool, where for each sensor it is possible to find documentation, javascript examples for parsing, downlink generator and uplink decoder:
  
 [[https://iot.mcf88.cloud/LoRaWeb/#/configuration|LoRaWEB Tool]] (iot.mcf88.cloud/LoRaWeb) [[https://iot.mcf88.cloud/LoRaWeb/#/configuration|LoRaWEB Tool]] (iot.mcf88.cloud/LoRaWeb)
Line 433: Line 442:
 ===== 9 Ordering code ===== ===== 9 Ordering code =====
  
-^Ordering Code  ^Description  | +^ Ordering Code  ^ Description                                         ^ 
-|EGK-LW20W00  |  LoRaWAN® waste level sensor +| EGK-LW20W00    | LoRaWAN® waste level sensor                         | 
-|EGK-RAWALL  |Wall mount bracket  |+| EGK-LW20W10    |  LoRaWAN® waste level sensor with external antenna  | 
 +| EGK-RAWALL     | Wall mount bracket                                  |
  
 ===== 10 Declaration of conformity ===== ===== 10 Declaration of conformity =====
  
-Hereby, enginko Srl declares that EGK-LW20W00 complies with the essential requirements and other relevant provisions of Directive 2014/53/EU.+Declarations of conformity are available from Angel4Future by sending a request email to sensor@enginko.com.
  
 ===== 11 Contacts ===== ===== 11 Contacts =====
  
-**enginko Srl** \\ Via Roma 3 I-28060 Sozzago (NO) \\ T : +39 0321 15 93 088+**Angel4Future S.r.l.** \\  
 +Via San Sabino 21 70042 MOLA DI BARI (BA, ITALY \\  
 +    +39 080 532 1796 \\  
  
-E : info@enginko.com \\ PEC: enginkosrl@legalmail.it \\ W: enginko.com+    info@angel4future.com  \\  
 +W:     enginko.com \\ 
  
 ---- ----
  
-Document rev. 4+Document rev. 5
  
 ---- ----