Plugin name 'sidebar.BROKEN' is not a valid plugin name, only the characters a-z and 0-9 are allowed. Maybe the plugin has been installed in the wrong directory?

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
manual_egk-lw22plg [2024/02/14 09:18] – [10 Ordering code] supportadminmanual_egk-lw22plg [2025/02/28 12:45] (current) – [11 Declaration of conformity] supportadmin
Line 10: Line 10:
  
   * Do not dismantle or modify in any way.   * Do not dismantle or modify in any way.
-  * The device is not intended to be used as a reference sensor, and enginko Srl will not be held liable for any damage which may result from inaccurate readings.+  * The device is not intended to be used as a reference sensor, and Angel4Future Srl will not be held liable for any damage which may result from inaccurate readings.
   * Avoid mechanical stress   * Avoid mechanical stress
   *  Do not use any detergent or alcohol to clean the device.   *  Do not use any detergent or alcohol to clean the device.
 +  * The device can only be connected to sockets with protective earth contact.
 +  * Risk of explosion if the battery is replaced with an incorrect type
 +  * Risk of explosion if the battery pack is subjected to a short circuit
 +  * Risk of explosion if the battery is burned or placed near high heat sources
 +  * Risk of explosion if the battery is crushed, punctured or cut
 +  * Do not expose the battery to contact with liquid substances.
  
 === Disposal information for users === === Disposal information for users ===
Line 31: Line 37:
 ===== 2. Overview ===== ===== 2. Overview =====
  
-==== 2.1 Technical data ====+==== 2.1 Technical data ====
  
   * CPU ARM Cortex M4   * CPU ARM Cortex M4
Line 39: Line 45:
   * Configurable default power-on status   * Configurable default power-on status
   * Instantaneous reading of active, reactive and apparent power, voltage and current   * Instantaneous reading of active, reactive and apparent power, voltage and current
-  * Power supply from line, 250 VAC, 50 Hz+  * Power supply from line, 230 VAC, 50 Hz
   * Bicolor led (green, blue), for output and LoRaWAN status   * Bicolor led (green, blue), for output and LoRaWAN status
   * Overload protection   * Overload protection
   * Rechargeable battery for powerline outage detection   * Rechargeable battery for powerline outage detection
   * Embedded antenna   * Embedded antenna
-  * Pushbutton  for forcing transmission or Re-Join, ON/OFF (lockable),+  * Pushbutton for forcing transmission or Re-Join, ON/OFF (lockable),
   * Time interval based or thresholds based uplink   * Time interval based or thresholds based uplink
   * Transmission @ 868 MHZ, 14dBm max.   * Transmission @ 868 MHZ, 14dBm max.
Line 50: Line 56:
   * Remote configuration   * Remote configuration
   * Storage temperature -10°C ÷ +70°C   * Storage temperature -10°C ÷ +70°C
-  * Working temperature -10°C ÷ +60°C+  * Working temperature -10°C ÷ +40°C ((Working temperature -10°C ÷ +50°C limited to a 12A current max))
   * Dimensions: 110x62x35mm   * Dimensions: 110x62x35mm
   * Protection grade: IP20   * Protection grade: IP20
   * Weight: 140g   * Weight: 140g
-   
  
  
Line 186: Line 191:
  
 |Contact mode  |SPDT  | |Contact mode  |SPDT  |
-|Maximum switching voltage  |250Vac~  |+|Maximum switching voltage  |230Vac~  |
 |Max. current  |16A  | |Max. current  |16A  |
  
Line 205: Line 210:
 {{ :wiki:manual_mcf-lw12met:calendar_table.jpg?direct&600 |}} {{ :wiki:manual_mcf-lw12met:calendar_table.jpg?direct&600 |}}
  
-===== 5 LoRaWAN network =====+===== 5 LoRaWAN network =====
  
-The sensor is compliant with LoRaWAN(r) specification 1.0.2.+The sensor is compliant with__** <font inherit/inherit;;inherit;;#66ff99>LoRaWAN® specification 1.0.2, regional 1.0.2b, class C.</font> **__
  
 +{{  :wiki:manual_mcf-lw12co2e:activation2_0.jpg?400  |activation2_0.jpg}}
  
-{{ :wiki:manual_mcf-lw12co2e:activation2_0.jpg?400 |}} 
  
 ==== 5.1 Activation ==== ==== 5.1 Activation ====
Line 222: Line 227:
 {{ :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400 |}} {{ :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400 |}}
  
-The device exits factory activated with **NONE** mode.+The device exits factory activated with **OTAA ENGINKO** mode.
 On request devices can be shipped already activated. On request devices can be shipped already activated.
  
Line 349: Line 354:
  
  
-To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko (please provide the DevEUI of the sensor when you ask for that code).+To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future (please provide the DevEUI of the sensor when you ask for that code).
  
 ===== 7 Configuration file =====  ===== 7 Configuration file =====
  
-WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in +WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in 
 case of multiple devices configuration. case of multiple devices configuration.
  
-With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to enginko's support if needed.+With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to Angel4Future's support if needed.
  
  
Line 387: Line 392:
  
  
-For details on files format please ask to enginko.+For details on files format please ask to Angel4Future.
 ===== 8 LoRaWEB Tool ===== ===== 8 LoRaWEB Tool =====
  
-enginko provides, upon free registration, **LoRaWEB** online tool,  where for each sensor it is possible to find documentation, javascript examples for parsing, downlink generator and uplink decoder:+Angel4Future provides free **LoRaWEB** online tool,  where for each sensor it is possible to find documentation, javascript examples for parsing, downlink generator and uplink decoder:
  
 [[https://iot.mcf88.cloud/LoRaWeb/#/configuration|LoRaWEB Tool]] [[https://iot.mcf88.cloud/LoRaWeb/#/configuration|LoRaWEB Tool]]
Line 413: Line 418:
 ^Ordering Code  ^Description| ^Ordering Code  ^Description|
 |EGK-LW22PLG|  LoRaWAN® energy meter plug with ON/OFF  | |EGK-LW22PLG|  LoRaWAN® energy meter plug with ON/OFF  |
 +|EGK-LW22PLG01|  LoRaWAN® energy meter plug with ON/OFF UK version  |
  
  
 ===== 11 Declaration of conformity ===== ===== 11 Declaration of conformity =====
  
-Hereby, enginko Srl declares that EGK-LW22PLG complies with the essential requirements and other relevant provisions of Directive  2014/53/EU.+Declarations of conformity are available from Angel4Future by sending a request email to sensor@enginko.com.
  
  
 ===== 12 Contacts ===== ===== 12 Contacts =====
  
-**enginko Srl** \\  +**Angel4Future S.r.l.** \\  
-Via Roma 3  I-28060 Sozzago (NO) \\  +Via San Sabino 21 70042 MOLA DI BARI (BA, ITALY \\  
-T  :    +39 0321 15 93 088 \\  +T  :    +39 080 532 1796 \\  
  
-E  :    info@enginko.com  \\  +E  :    info@angel4future.com  \\ 
-PEC: enginkosrl@legalmail.it \\ +
 W:     enginko.com \\  W:     enginko.com \\ 
  
 ---- ----
-Document rev. 1+Document rev. 2
 ---- ----