Plugin name 'sidebar.BROKEN' is not a valid plugin name, only the characters a-z and 0-9 are allowed. Maybe the plugin has been installed in the wrong directory?

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
manual_mcf-lw12co2e [2021/11/23 12:09] – [5.1 Activation] supportadminmanual_mcf-lw12co2e [2025/11/06 16:28] (current) – [10 Declaration of conformity] supportadmin
Line 11: Line 11:
   * Do not dismantle or modify in any way.   * Do not dismantle or modify in any way.
   * The device is only intended for indoor use. Do not expose it to moisture.   * The device is only intended for indoor use. Do not expose it to moisture.
-  * The device is not intended to be used as a reference sensor, and enginko Srl will not be held liable for any damage which may result from inaccurate readings.+  * The device is not intended to be used as a reference sensor, and Angel4Future Srl will not be held liable for any damage which may result from inaccurate readings.
   * Avoid mechanical stress   * Avoid mechanical stress
   *  Do not use any detergent or alcohol to clean the device.   *  Do not use any detergent or alcohol to clean the device.
Line 149: Line 149:
 === 2.5.1 Battery replacement ===  === 2.5.1 Battery replacement ===
  
-Battery packs must be replaced together, do not let the sensor run with batry packs with different levels of charge.+Battery packs must be replaced together, do not let the sensor run with battery packs with different levels of charge.
  
   * remove the back panel of the sensor with a small screwdriver:   * remove the back panel of the sensor with a small screwdriver:
Line 173: Line 173:
 __After the batteries replacement, internal counters need to be resetted.__ __After the batteries replacement, internal counters need to be resetted.__
  
-{{ :wiki:manual_mcf-lw12co2e:battery1_res_0.jpg?400 |}}+{{ :wiki:manual_mcf-lw12terwp:batt_res.jpg?400 |}}
  
-To perform the operation, you need a unique reset code that must be requested to enginko (please provide the DevEUI of the sensor when you ask for that code):+To perform the operation, you need a unique reset code that must be requested to Angel4Future (please provide the DevEUI of the sensor when you ask for that code):
      
 {{ :wiki:manual_mcf-lw12co2e:battery_res_0.jpg?400 |}} {{ :wiki:manual_mcf-lw12co2e:battery_res_0.jpg?400 |}}
Line 182: Line 182:
 ==== 2.6 Firmware update====  ==== 2.6 Firmware update====
  
-Save the firmware file (.FW) on the smartphone, and upload it with LoraTool App:+Download the latest firmwares available on the smartphone with LoRaTool app: 
 + 
 +{{ :wiki:manual_egk-lw20w00:update_firmwares.jpg?direct&400 |}} 
 + 
 +{{ :wiki:manual_egk-lw22plg:fwdownload.jpg?nolink&400 |}} 
 + 
 +{{ :wiki:manual_egk-lw22plg:fwdownload1.jpg?nolink&400 |}} 
 + 
 +Update the sensor with LoRaTool:
  
 {{ :wiki:manual_mcf-lw12co2e:fw_0.jpg?400 |}} {{ :wiki:manual_mcf-lw12co2e:fw_0.jpg?400 |}}
Line 269: Line 277:
 Due to the internal automatic calibration algorithm (enabled as default), the sensor must be exposed to true fresh air environment at least once a week.  Due to the internal automatic calibration algorithm (enabled as default), the sensor must be exposed to true fresh air environment at least once a week. 
  
-If such an environment can never be expected to occur, either by sensor locality or ever-presence of CO2 emission sources (for example gree-house), or exposure to even lower concentrations than the natural fresh air baseline, the automatic calibration must be disabled with LoRa Tool app:+If such an environment can never be expected to occur, either by sensor locality or ever-presence of CO2 emission sources (for example green-house), or exposure to even lower concentrations than the natural fresh air baseline, the automatic calibration must be disabled with LoRa Tool app:
  
 {{ :wiki:manual_mcf-lw12co2e:co2_calib_0.jpg?400 |}} {{ :wiki:manual_mcf-lw12co2e:co2_calib_0.jpg?400 |}}
  
-Calibation can also be foced with special downlinks commmands (available on request).+Calibration can also be forced with special downlinks commmands (available on request).
  
  
Line 325: Line 333:
  
  
-===== 5 LoRaWAN(r) network =====+===== 5 LoRaWAN network =====
  
-The sensor is compliant with LoRaWAN(r) specification 1.0.2, regional 1.0.2b.+The sensor is compliant with LoRaWAN(r) **specification 1.0.2****regional 1.0.2b**.
  
  
Line 342: Line 350:
 {{ :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400 |}} {{ :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400 |}}
  
-The device exits factory activated with **NONE** mode.+The device exits factory activated with **OTAA ENGINKO** mode.
 On request devices can be shipped aleady activated. On request devices can be shipped aleady activated.
  
 Note: in **OTAA** AppKey is write only, in reading the field will always be empty, even if set. Note: in **OTAA** AppKey is write only, in reading the field will always be empty, even if set.
  
------ 
- === Time sync == 
  
-{{:warning.png?50|}} 
- 
-Normally sensor asks for a time sync at every power on (uplink starting with 01) or once a week. 
-If no or wrong reply received it will retry after 1 hour. 
-  
-  
-If not handled in the right way can cause a unnecessary battery consumption (battery life < 2 years). 
- 
-Please check chapter 2.1 of "DATA FRAME FORMAT" document. 
    
    
Line 385: Line 382:
 **No time sync**:\\ **No time sync**:\\
 set to disable time synchronization request (default: enabled). set to disable time synchronization request (default: enabled).
 +
 +-----
 +{{:warning.png?40|}}
 +
 +Normally sensor asks for a time sync at every power on (uplink starting with 01) or, if enabled, once a week.
 +
 +If not handled in the right way can cause a unnecessary battery consumption (battery life < 2 years).
 +
 +Please check chapter 2.1 [[data_frame_format| DATA FRAME FORMAT]].
 +-----
  
 **UnConfirmed**:\\ **UnConfirmed**:\\
Line 421: Line 428:
  
  
-To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko (please provide the DevEUI of the sensor when you ask for that code).+To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future (please provide the DevEUI of the sensor when you ask for that code).
  
 ===== 7 Configuration file =====  ===== 7 Configuration file =====
  
-WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in +WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in 
 case of multiple devices configuration. case of multiple devices configuration.
  
-With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to enginko's support if needed.+With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to Angel4Future's support if needed.
  
  
Line 446: Line 453:
 When the sensor is approached, if one parameter is different from files, the APP will ask you if you want to overwrite. When the sensor is approached, if one parameter is different from files, the APP will ask you if you want to overwrite.
    
-XLS is prevailing on the XML, so if both files are enabled, if the DevEUI of the device matches one of the DevEUIS is in the XLS file, LoRa parameters will be setted from this one.+XLS is prevailing on the XML, so if both files are enabled, if the DevEUI of the device matches one of the DevEUIs in the XLS file, LoRa parameters will be setted from this one.
  
 These configuration can be done in the in the Settings: These configuration can be done in the in the Settings:
Line 459: Line 466:
  
  
-For details on files format please ask to enginko.+For details on files format please ask to Angel4Future.
 ===== 8 LoRaWEB Tool ===== ===== 8 LoRaWEB Tool =====
  
-enginko provides, upon free registration, **LoRaWEB** online tool,  where for each sensor it is possible to find documentation, javascript examples for parsing, downlink generator and uplink decoder:+Angel4Future provides free **LoRaWEB** online tool,  where for each sensor it is possible to find documentation, javascript examples for parsing, downlink generator and uplink decoder:
  
 [[https://iot.mcf88.cloud/LoRaWeb/#/configuration|LoRaWEB Tool]] [[https://iot.mcf88.cloud/LoRaWeb/#/configuration|LoRaWEB Tool]]
Line 478: Line 485:
 [[data_frame_format| DATA FRAME FORMAT]] [[data_frame_format| DATA FRAME FORMAT]]
  
-===== 10 Declaration of conformity =====+===== 10 Declaration of conformity =====
  
-Hereby, enginko Srl declares that MCF-LW12CO2E complies with the essential requirements and other relevant provisions of Directive  2014/53/EU.+Declarations of conformity are available from Angel4Future by sending a request email to sensors@enginko.com.
  
  
 ===== 11 Contacts ===== ===== 11 Contacts =====
  
-**enginko Srl** \\  +**Angel4Future S.r.l.** \\  
-Via Roma 3  I-28060 Sozzago (NO) \\  +Via San Sabino 21 70042 MOLA DI BARI (BA, ITALY \\  
-T  :    +39 0321 15 93 088 \\  +T  :    +39 080 532 1796 \\  
  
-E  :    info@enginko.com  \\  +E  :    info@angel4future.com  \\ 
-PEC: enginkosrl@legalmail.it \\ +
 W:     enginko.com \\  W:     enginko.com \\ 
  
 ---- ----