This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| manual_mcf-lw12co2e [2022/01/24 15:24] – [5.1 Activation] supportadmin | manual_mcf-lw12co2e [2025/11/06 16:28] (current) – [10 Declaration of conformity] supportadmin | ||
|---|---|---|---|
| Line 11: | Line 11: | ||
| * Do not dismantle or modify in any way. | * Do not dismantle or modify in any way. | ||
| * The device is only intended for indoor use. Do not expose it to moisture. | * The device is only intended for indoor use. Do not expose it to moisture. | ||
| - | * The device is not intended to be used as a reference sensor, and enginko | + | * The device is not intended to be used as a reference sensor, and Angel4Future |
| * Avoid mechanical stress | * Avoid mechanical stress | ||
| * Do not use any detergent or alcohol to clean the device. | * Do not use any detergent or alcohol to clean the device. | ||
| Line 175: | Line 175: | ||
| {{ : | {{ : | ||
| - | To perform the operation, you need a unique reset code that must be requested to enginko | + | To perform the operation, you need a unique reset code that must be requested to Angel4Future |
| | | ||
| {{ : | {{ : | ||
| Line 182: | Line 182: | ||
| ==== 2.6 Firmware update==== | ==== 2.6 Firmware update==== | ||
| - | Save the firmware file (.FW) on the smartphone, and upload it with LoraTool App: | + | Download |
| + | |||
| + | {{ : | ||
| + | |||
| + | {{ : | ||
| + | |||
| + | {{ : | ||
| + | |||
| + | Update the sensor with LoRaTool: | ||
| {{ : | {{ : | ||
| Line 269: | Line 277: | ||
| Due to the internal automatic calibration algorithm (enabled as default), the sensor must be exposed to true fresh air environment at least once a week. | Due to the internal automatic calibration algorithm (enabled as default), the sensor must be exposed to true fresh air environment at least once a week. | ||
| - | If such an environment can never be expected to occur, either by sensor locality or ever-presence of CO2 emission sources (for example | + | If such an environment can never be expected to occur, either by sensor locality or ever-presence of CO2 emission sources (for example |
| {{ : | {{ : | ||
| - | Calibation | + | Calibration |
| Line 342: | Line 350: | ||
| {{ : | {{ : | ||
| - | The device exits factory activated with **NONE** mode. | + | The device exits factory activated with **OTAA ENGINKO** mode. |
| On request devices can be shipped aleady activated. | On request devices can be shipped aleady activated. | ||
| Line 374: | Line 382: | ||
| **No time sync**:\\ | **No time sync**:\\ | ||
| set to disable time synchronization request (default: enabled). | set to disable time synchronization request (default: enabled). | ||
| + | |||
| + | ----- | ||
| + | {{: | ||
| + | |||
| + | Normally sensor asks for a time sync at every power on (uplink starting with 01) or, if enabled, once a week. | ||
| + | |||
| + | If not handled in the right way can cause a unnecessary battery consumption (battery life < 2 years). | ||
| + | |||
| + | Please check chapter 2.1 [[data_frame_format| DATA FRAME FORMAT]]. | ||
| + | ----- | ||
| **UnConfirmed**: | **UnConfirmed**: | ||
| Line 410: | Line 428: | ||
| - | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko | + | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future |
| ===== 7 Configuration file ===== | ===== 7 Configuration file ===== | ||
| - | WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in | + | WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in |
| case of multiple devices configuration. | case of multiple devices configuration. | ||
| - | With " | + | With " |
| Line 435: | Line 453: | ||
| When the sensor is approached, if one parameter is different from files, the APP will ask you if you want to overwrite. | When the sensor is approached, if one parameter is different from files, the APP will ask you if you want to overwrite. | ||
| - | XLS is prevailing on the XML, so if both files are enabled, if the DevEUI of the device matches one of the DevEUIS is in the XLS file, LoRa parameters will be setted from this one. | + | XLS is prevailing on the XML, so if both files are enabled, if the DevEUI of the device matches one of the DevEUIs |
| These configuration can be done in the in the Settings: | These configuration can be done in the in the Settings: | ||
| Line 448: | Line 466: | ||
| - | For details on files format please ask to enginko. | + | For details on files format please ask to Angel4Future. |
| ===== 8 LoRaWEB Tool ===== | ===== 8 LoRaWEB Tool ===== | ||
| - | enginko | + | Angel4Future |
| [[https:// | [[https:// | ||
| Line 467: | Line 485: | ||
| [[data_frame_format| DATA FRAME FORMAT]] | [[data_frame_format| DATA FRAME FORMAT]] | ||
| - | ===== 10 Declaration of conformity ===== | + | ===== 10 Declaration of conformity ===== |
| - | Hereby, enginko Srl declares that MCF-LW12CO2E complies with the essential requirements and other relevant provisions | + | Declarations |
| ===== 11 Contacts ===== | ===== 11 Contacts ===== | ||
| - | **enginko Srl** \\ | + | **Angel4Future S.r.l.** \\ |
| - | Via Roma 3 I-28060 Sozzago | + | Via San Sabino 21 - 70042 MOLA DI BARI (BA) , ITALY \\ |
| - | T : +39 0321 15 93 088 \\ | + | T : +39 080 532 1796 \\ |
| - | E : info@enginko.com | + | E : info@angel4future.com \\ |
| - | PEC: enginkosrl@legalmail.it | + | |
| W: | W: | ||
| ---- | ---- | ||