This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| manual_mcf-lw12met [2023/03/14 10:33] – [5.2 Other settings] supportadmin | manual_mcf-lw12met [2025/02/28 12:46] (current) – [11 Declaration of conformity] supportadmin | ||
|---|---|---|---|
| Line 11: | Line 11: | ||
| * Do not dismantle or modify in any way. | * Do not dismantle or modify in any way. | ||
| * Avoid mechanical stress | * Avoid mechanical stress | ||
| - | * The device is not intended to be used as a reference sensor, and enginko Srl will not be held liable for any damage which may result from inaccurate readings. | + | * The device is not intended to be used as a reference sensor, and Angel4FutureSrl |
| * Do not use any detergent or alcohol to clean the device. | * Do not use any detergent or alcohol to clean the device. | ||
| * Do not mount in horizontal position. | * Do not mount in horizontal position. | ||
| Line 254: | Line 254: | ||
| {{ : | {{ : | ||
| - | The device exits factory activated with **NONE** mode. | + | The device exits factory activated with **OTAA ENGINKO** mode. |
| On request devices can be shipped aleady activated. | On request devices can be shipped aleady activated. | ||
| Line 282: | Line 282: | ||
| - | {{ : | ||
| **OUT**:\\ | **OUT**:\\ | ||
| set to force a change of the output (default: off). | set to force a change of the output (default: off). | ||
| Line 383: | Line 382: | ||
| - | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko | + | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future |
| ===== 7 Configuration file ===== | ===== 7 Configuration file ===== | ||
| - | WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in | + | WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in |
| case of multiple devices configuration. | case of multiple devices configuration. | ||
| - | With " | + | With " |
| Line 421: | Line 420: | ||
| - | For details on files format please ask to enginko. | + | For details on files format please ask to Angel4Future. |
| ===== 8 LoRaWEB Tool ===== | ===== 8 LoRaWEB Tool ===== | ||
| - | enginko | + | Angel4Future |
| [[https:// | [[https:// | ||
| Line 452: | Line 451: | ||
| ===== 11 Declaration of conformity ===== | ===== 11 Declaration of conformity ===== | ||
| - | Hereby, enginko Srl declares that MCF-LW12MET complies with the essential requirements and other relevant provisions | + | Declarations |
| ===== 12 Contacts ===== | ===== 12 Contacts ===== | ||
| - | **enginko Srl** \\ | + | **Angel4Future S.r.l.** \\ |
| - | Via Roma 3 I-28060 Sozzago | + | Via San Sabino 21 - 70042 MOLA DI BARI (BA) , ITALY \\ |
| - | T : +39 0321 15 93 088 \\ | + | T : +39 080 532 1796 \\ |
| - | E : info@enginko.com | + | E : info@angel4future.com \\ |
| - | PEC: enginkosrl@legalmail.it | + | W: |
| - | W: | + | |
| ---- | ---- | ||
| - | rev. 0 | + | rev. 1 |