Plugin name 'sidebar.BROKEN' is not a valid plugin name, only the characters a-z and 0-9 are allowed. Maybe the plugin has been installed in the wrong directory?

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
manual_mcf-lwws0x [2025/02/14 17:41] – [2.2 Installation] supportadminmanual_mcf-lwws0x [2025/09/08 15:03] (current) – [2.1 Technical data] sensors
Line 9: Line 9:
  
   * Do not dismantle or modify in any way.   * Do not dismantle or modify in any way.
-  * The device is not intended to be used as a reference sensor, and enginko Srl will not be held liable for any damage which may result from inaccurate readings.+  * The device is not intended to be used as a reference sensor, and Angel4Future Srl will not be held liable for any damage which may result from inaccurate readings.
   * Avoid mechanical stress   * Avoid mechanical stress
   * Do not use any detergent or alcohol to clean the device.   * Do not use any detergent or alcohol to clean the device.
Line 54: Line 54:
  
 Based on the different version, some sensors can be not present. Based on the different version, some sensors can be not present.
-==== 2.1 Technical data ====+==== 2.1 Technical data ====
  
   * CPU Cortex M0+   * CPU Cortex M0+
Line 75: Line 75:
   * 5W Solar panel powered with 6V12Ah battery   * 5W Solar panel powered with 6V12Ah battery
   * Mounting Tripod with Lag Bolts   * Mounting Tripod with Lag Bolts
 +  * Estimated Battery Run Time (fully charged, in darkness): over 60 days.
  
 +Power consumption of the LoRaWAN interface (with no PM sensor): \\ - floor current: 500uA; \\ - 600mW for a duration of 2 seconds for every LoRaWAN transmission (worst case); \\ - 800uA as average with 1 message every 15 minutes, SF = 12; \\ - PM sensor additional average consumption: 1.8mA (1 measure every 15 minutes).
  
-Power consumption of the LoRaWAN interface (with no PM sensor):\\ +=== 2.1.1 Davis Instruments detailed data ===
- - floor current: 500uA;\\ +
- - 600mW for a duration of 2 seconds for every LoRaWAN transmission (worst case);\\ +
- - 800uA as average with 1 message every 15 minutes, SF 12;\\ +
- - PM sensor additional average consumption: 1.8mA (measure every 15 minutes).+
  
-=== 2.1.1 Davis Instruments detailed data === +^Version  ^Davis Code  ^Description|
- +
-^Version ^Davis Code ^Description ^+
 |MCF-LWWS00/01|6820CM|[[https://cdn.shopify.com/s/files/1/0515/5992/3873/files/6820_6820C_Spec_Sheet_Web.pdf?v=1631307649|ISS Davis Vantage Pro2 Groweather]]| |MCF-LWWS00/01|6820CM|[[https://cdn.shopify.com/s/files/1/0515/5992/3873/files/6820_6820C_Spec_Sheet_Web.pdf?v=1631307649|ISS Davis Vantage Pro2 Groweather]]|
 |MCF-LWWS02/03|6322CM|[[https://cdn.shopify.com/s/files/1/0515/5992/3873/files/6152_62_53_63_ss.pdf?v=1623783718|ISS Davis Vantage Pro2]]| |MCF-LWWS02/03|6322CM|[[https://cdn.shopify.com/s/files/1/0515/5992/3873/files/6152_62_53_63_ss.pdf?v=1623783718|ISS Davis Vantage Pro2]]|
Line 123: Line 119:
   - Fasten the 6316CEU to the box   - Fasten the 6316CEU to the box
   - Connect the red wire terminal “B” to the positive terminal of the battery “C”.   - Connect the red wire terminal “B” to the positive terminal of the battery “C”.
-  - Connect the white connector to the LoRaWAN® interface "D".+  - Connect the white connectors to the LoRaWAN® interface.
  
 {{  :wiki:manual_mcf-lwws0x:envoy_lock.jpg?600  |envoy_lock.jpg}} {{  :wiki:manual_mcf-lwws0x:envoy_lock.jpg?600  |envoy_lock.jpg}}
  
-{{  :wiki:manual_mcf-lwws0x:power.jpg?600  |power.jpg}}+{{  :wiki:manual_mcf-lwws0x:power1.jpg?600  |power1.jpg}}
  
 Power can also be supplied by USB, //**only for configuration, not for normal use**// . Power can also be supplied by USB, //**only for configuration, not for normal use**// .
Line 163: Line 159:
  
  
-enginko provides, upon free registration,  user manuals, javascript examples, downlink generator, uplink decoder, firmware updates and different tools :+Angel4Future provides  user manuals, javascript examples, downlink generator, uplink decoder, firmware updates and different tools :
  
  
Line 273: Line 269:
 {{ :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400 |}} {{ :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400 |}}
  
-The device exits factory activated with **NONE** mode.+The device exits factory activated with **OTAA ENGINKO** mode.
 On request devices can be shipped aleady activated. On request devices can be shipped aleady activated.
  
Line 317: Line 313:
  
  
-To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko (please provide the DevEUI of the sensor when you ask for that code).+To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future (please provide the DevEUI of the sensor when you ask for that code).
  
 ===== 7 Configuration file =====  ===== 7 Configuration file =====
  
-With LoRaWEB is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in +With LoRaWEB is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in 
 case of multiple devices configuration. case of multiple devices configuration.
  
-With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to enginko's support if needed.+With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to Angel4Future's support if needed.
  
  
Line 349: Line 345:
  
  
-For details on files format please ask to enginko.+For details on files format please ask to Angel4Future.
  
 ===== 8 Payload ===== ===== 8 Payload =====
Line 400: Line 396:
 ===== 12 Declaration of conformity ===== ===== 12 Declaration of conformity =====
  
-Hereby, enginko Srl declares that MCF-LWWS0x complies with the essential requirements and other relevant provisions of Directive  2014/53/EU.+Declarations of conformity are available from Angel4Future by sending a request email to sensor@enginko.com.EU.
  
  
 ===== 13 Contacts ===== ===== 13 Contacts =====
  
-**enginko Srl** \\  +**Angel4Future S.r.l.** \\  
-Via Roma 3  I-28060 Sozzago (NO) \\  +Via San Sabino 21 70042 MOLA DI BARI (BA, ITALY \\  
-T  :    +39 0321 15 93 088 \\  +T  :    +39 080 532 1796 \\  
  
-E  :    info@enginko.com  \\  +E  :    info@angel4future.com  \\ 
-PEC: enginkosrl@legalmail.it \\ +
 W:     enginko.com \\  W:     enginko.com \\