This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| manual_mcf-lwws0x [2025/02/14 17:41] – [2.2 Installation] supportadmin | manual_mcf-lwws0x [2025/09/08 15:03] (current) – [2.1 Technical data] sensors | ||
|---|---|---|---|
| Line 9: | Line 9: | ||
| * Do not dismantle or modify in any way. | * Do not dismantle or modify in any way. | ||
| - | * The device is not intended to be used as a reference sensor, and enginko | + | * The device is not intended to be used as a reference sensor, and Angel4Future |
| * Avoid mechanical stress | * Avoid mechanical stress | ||
| * Do not use any detergent or alcohol to clean the device. | * Do not use any detergent or alcohol to clean the device. | ||
| Line 54: | Line 54: | ||
| Based on the different version, some sensors can be not present. | Based on the different version, some sensors can be not present. | ||
| - | ==== 2.1 Technical data ==== | + | ==== 2.1 Technical data ==== |
| * CPU Cortex M0+ | * CPU Cortex M0+ | ||
| Line 75: | Line 75: | ||
| * 5W Solar panel powered with 6V12Ah battery | * 5W Solar panel powered with 6V12Ah battery | ||
| * Mounting Tripod with Lag Bolts | * Mounting Tripod with Lag Bolts | ||
| + | * Estimated Battery Run Time (fully charged, in darkness): over 60 days. | ||
| + | Power consumption of the LoRaWAN interface (with no PM sensor): \\ - floor current: 500uA; \\ - 600mW for a duration of 2 seconds for every LoRaWAN transmission (worst case); \\ - 800uA as average with 1 message every 15 minutes, SF = 12; \\ - PM sensor additional average consumption: | ||
| - | Power consumption of the LoRaWAN interface (with no PM sensor): | + | === 2.1.1 Davis Instruments detailed data === |
| - | - floor current: 500uA;\\ | + | |
| - | - 600mW for a duration of 2 seconds for every LoRaWAN transmission (worst case);\\ | + | |
| - | - 800uA as average with 1 message every 15 minutes, SF = 12;\\ | + | |
| - | - PM sensor additional average consumption: | + | |
| - | === 2.1.1 Davis Instruments detailed data === | + | ^Version |
| - | + | ||
| - | ^Version ^Davis Code ^Description | + | |
| |MCF-LWWS00/ | |MCF-LWWS00/ | ||
| |MCF-LWWS02/ | |MCF-LWWS02/ | ||
| Line 123: | Line 119: | ||
| - Fasten the 6316CEU to the box | - Fasten the 6316CEU to the box | ||
| - Connect the red wire terminal “B” to the positive terminal of the battery “C”. | - Connect the red wire terminal “B” to the positive terminal of the battery “C”. | ||
| - | - Connect the white connector | + | - Connect the white connectors |
| {{ : | {{ : | ||
| - | {{ : | + | {{ : |
| Power can also be supplied by USB, //**only for configuration, | Power can also be supplied by USB, //**only for configuration, | ||
| Line 163: | Line 159: | ||
| - | enginko | + | Angel4Future |
| Line 273: | Line 269: | ||
| {{ : | {{ : | ||
| - | The device exits factory activated with **NONE** mode. | + | The device exits factory activated with **OTAA ENGINKO** mode. |
| On request devices can be shipped aleady activated. | On request devices can be shipped aleady activated. | ||
| Line 317: | Line 313: | ||
| - | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko | + | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future |
| ===== 7 Configuration file ===== | ===== 7 Configuration file ===== | ||
| - | With LoRaWEB is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in | + | With LoRaWEB is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in |
| case of multiple devices configuration. | case of multiple devices configuration. | ||
| - | With " | + | With " |
| Line 349: | Line 345: | ||
| - | For details on files format please ask to enginko. | + | For details on files format please ask to Angel4Future. |
| ===== 8 Payload ===== | ===== 8 Payload ===== | ||
| Line 400: | Line 396: | ||
| ===== 12 Declaration of conformity ===== | ===== 12 Declaration of conformity ===== | ||
| - | Hereby, enginko Srl declares that MCF-LWWS0x complies with the essential requirements and other relevant provisions | + | Declarations |
| ===== 13 Contacts ===== | ===== 13 Contacts ===== | ||
| - | **enginko Srl** \\ | + | **Angel4Future S.r.l.** \\ |
| - | Via Roma 3 I-28060 Sozzago | + | Via San Sabino 21 - 70042 MOLA DI BARI (BA) , ITALY \\ |
| - | T : +39 0321 15 93 088 \\ | + | T : +39 080 532 1796 \\ |
| - | E : info@enginko.com | + | E : info@angel4future.com \\ |
| - | PEC: enginkosrl@legalmail.it | + | |
| W: | W: | ||