===== ===== {{ :enginko_logo_colori_exe.jpg?nolink&200 |}} ===== MCF-LW12TER Operating Manual===== === Important safety information === {{::warning.png?80 |}}Read this manual before attempting to install the device! Failure to observe recommendations included in this manual may be dangerous or cause a violation of the law. The manufacturer will not be held responsible for any loss or damage resulting from not following the instructions of this operating manual. * Do not dismantle or modify in any way. * The device is only intended for indoor use. Do not expose it to moisture. * The device is not intended to be used as a reference sensor, and Angel4Future Srl will not be held liable for any damage which may result from inaccurate readings. * Avoid mechanical stress * Do not use any detergent or alcohol to clean the device. === Disposal information for users === {{:wiki:manual_mcf-lw12co2e:1200px-weee_symbol_vectors.svg.png?50 |}}**Pursuant to and in accordance with Article 14 of the Directive 2012/19/EU of the European Parliament on waste electrical and electronic equipment (WEEE), and pursuant to and in accordance with Article 20 of the Directive 2013/56/EU of the European Parliament on batteries and accumulators and waste batteries. ** The barred symbol of the rubbish bin shown on the equipment indicates that, at the end of its useful life, the product must be collected separately from other waste. Please note that the lithium batteries must be removed from the equipment before it is given as waste and disposed separately. To remove the batteries refer to the specifications in the user manual. For additional information and how to carry out disposal, please contact the certified disposal service providers. ===== 1. Description ===== The MCF-LW12TER is a battery powered sensor for indoor applications that reads temperature, relative humidity and barometri pressure.The device sends collected data over the LoRaWAN(r) network. Ideally suited for a wide range of applications such as home buildings, air quality monitoring and energy saving applications. {{ :wiki:manual_mcf-lw12VOC:mcf-lw12TER.jpg?600 |}} ===== 2. Overview ===== ==== 2.1 Technical data ==== * Cortex M0 + CPU * EEProm 32Kb * 64k flash * AES 128 bit encryption * LoRaWAN(r) stack class A 1.0.2 EU868, AS923, AU915 and US915 * Temperature -10 ÷ 60°C (± 1.0°C, ± 0.5°C @ +25°C) * Humidity 0 ÷ 100% (20 ÷ 80% ± 3% @ 25°C, 0 ÷ 20% * 80 ÷ 100% ± 5% @ 25°C) * Pressure 300 ÷ 1100hPa (± 1hPa) * Battery powered with 6 years of battery life (SF = 12, 10 minutes reading period) * Battery capacity (included) 14400mAh * NFC for node configuration, FW update and data reading * Indoor installation * Storage temperature -20 + 80°C * Operating temperature -10 + 60°C * Dimensions: 80x80x25mm * Weight ~ 150g ==== 2.2 Installation ==== To ensure correct operation and reliable and consistent measurements, install the MCF-LW12TER sensor away from direct sunlight and heating sources like radiators, conveyors, TV, lights etc. and far away from doors and windows. {{ :wiki:manual_mcf-lw12co2e:position_rev0.jpg |}} The device must be placed where the LoRaWAN(r) signal coverage is good (SF = 7 optimal, SF = 12 weak). The sensor must be installed vertically on a wall at about 1.5mt height. It must be at least 30cm away from metal objects, and 1mt away from electronic devices. {{ :wiki:manual_mcf-lw12voc:dima_80_rev0.jpg?600 |}} === 2.2.1 LoRa Tool === To deploy the sensor, download the latest __**LoRa Tool**__ Android App to setup LoRaWAN credentials and other preferences : [[https://play.google.com/store/apps/details?id=com.mcf88.loratool.client&hl=en&gl=US|{{:wiki:manual_mcf-lw12co2e:lora_tool.jpg?100}}]] __Always validate your settings by reading the NFC data after the sensor has restarted.__ ==== 2.3 Power ON/OFF ==== The sensor is shipped completely off to prevent battery consumption during storage. It is therefore necessary to carry out a first power-on prior to commissioning. There are two ways to power on the sensor: * With NFC: Move the NFC antenna of the mobile (the exact position varies depending on the model of the smartphone) to the sensor antenna, in the area shown in the figure: {{ :wiki:manual_mcf-lw12VOC:nfc_ant_0.jpg?400 |}} * Mechanical power on: Open the case using a screw driver as follow: {{ :wiki:manual_mcf-lw12VOC:open_0.jpg?400 |}} By using a screw driver push button for 1s as follow, moving right: {{ :wiki:manual_mcf-lw12VOC:sw_0.jpg?400 |}} Close the plastic case. Switch-on is visible by flashing of red and green leds. In case of long period inactivity, if necessary, is possible to shut-off again the sensor to prevent battery consumption, via downlink or with LoRa Tool App: {{ :wiki:manual_mcf-lw12co2e:off_0.jpg?400 |}} ==== 2.4 System leds ==== {{ :wiki:manual_mcf-lw12voc:sysled_rev0.jpg?400 |}} |LoRaWAN(r) not configured| {{:wiki:manual_mcf-lw12co2e:gfrf_rev0.jpg?80|}} |Slow flashing| |Joining| {{:wiki:manual_mcf-lw12co2e:gfr_rev0.jpg?80|}} |Quick flashing| |Sending| {{:wiki:manual_mcf-lw12co2e:gf_ev0.jpg?40|}} |Quick flashing| |Receiving| {{:wiki:manual_mcf-lw12co2e:gf_ev0.jpg?40|}} |Quick flashing| |Steady state| {{:wiki:manual_mcf-lw12co2e:g_rev0.jpg?40|}} | Fixed | |Data error| {{:wiki:manual_mcf-lw12co2e:rf_rec0.jpg?40|}} |Flashing 2 seconds| |Connection error| {{:wiki:manual_mcf-lw12co2e:rf_rec0.jpg?40|}} |Flashing 1 second| ==== 2.5 Battery ==== This sensor contains lithium battery, which must be disposed of separately. MCF-LW12TER is provided with one Li-SOCl2 battery packs: ^Code ^Description ^ |MCF-1S4PE | 14400mAh battery pack | This is the estimated battery life (in **years**) in the worst conditions: | ^10min reading ^15min reading ^30min reading ^ ^SF12 | 7 | 10 | > 10 | ^SF7 | > 10 | > 10 | > 10 | === 2.5.1 Battery replacement === * remove the back panel of the sensor with a small screwdriver: {{ :wiki:manual_mcf-lw12VOC:open_0.jpg?400 |}} * detach the batteries from the electronic board (batteries are secured with dual locking tape) and disconnect from the connectors: {{ :wiki:manual_mcf-lw12VOC:connbatt_ev0.jpg?600 |}} * Connect the new batteries and put them in place (replace the tape if needed): {{ :wiki:manual_mcf-lw12VOC:connbatt1_ev0.jpg?600 |}} \\ {{ :wiki:manual_mcf-lw12VOC:connbatt3_rev0.jpg?400 | }} * Place the rear panel paying attention to the wires. __After the batteries replacement, internal counters need to be resetted.__ {{ :wiki:manual_mcf-lw12terwp:batt_res.jpg?400 |}} To perform the operation, you need a unique reset code that must be requested to Angel4Future (please provide the DevEUI of the sensor when you ask for that code): {{ :wiki:manual_mcf-lw12co2e:battery_res_0.jpg?400 |}} At the end of the procedure the battery level displays 100%. ==== 2.6 Firmware update==== Download the latest firmwares available on the smartphone with LoRaTool app: {{ :wiki:manual_egk-lw20w00:update_firmwares.jpg?direct&400 |}} {{ :wiki:manual_egk-lw22plg:fwdownload.jpg?nolink&400 |}} {{ :wiki:manual_egk-lw22plg:fwdownload1.jpg?nolink&400 |}} Update the sensor with LoRaTool: {{ :wiki:manual_mcf-lw12co2e:fw_0.jpg?400 |}} During the update, do not move the smartphone untill the end message. ===== 3 LEDs ===== On the MCF-LW12TER there are two system leds, green and red. ===== 4. Measures ===== {{ :wiki:manual_mcf-lw12ter:app_main_0.jpg?400 |}} ==== 4.1 Period ==== Period is the interval (in minutes) between one measure and the next one. The sensor sends three measures for every transmission (each one with its own timestamp), so the messages interval is twice the period value. Value can be between 10 and 65535 minutes. Period interval can be set with App or with downlink command. The device sends extra reports when the measurement changes in accordance with the set thresholds. ==== 4.2 Temperature ==== ==== 4.3 Pressure ==== === 4.3.1 Altitude compensation === When the sensor is not installed at the sea level, the reading of barometric pressures at other elevations must be compensated. Set the right altitude value with LoRa Tool app: {{ :wiki:manual_mcf-lw12co2e:settings_altitude_0.jpg?400 |}} Value can be from -300 to 3000 meters. Altitude can also be set with downlink command. ==== 4.4 Humidity ==== ===== 5 LoRaWAN network ===== The sensor is compliant with LoRaWAN(r) **specification 1.0.2**, **regional 1.0.2b**. {{ :wiki:manual_mcf-lw12co2e:activation2_0.jpg?400 |}} ==== 5.1 Activation ==== The device supports the following activations on a LoRaWAN(r) network: - **NONE**: sensor not activated - **OTAA**: the JoinEUI and the AppKey not setted, must be written to the device; - **OTAA MCF88**: Over the air activation, fixed keys: JoinEUI = 904e915000000001, AppKey on request; - **OTAA ENGINKO**: Over the air activation, fixed keys: JoinEUI = 904e915000000001, AppKey on request; - **ABP**: requires writing to the device of NwkSkey, AppSkey, DevAddr. {{ :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400 |}} The device exits factory activated with **OTAA ENGINKO** mode. On request devices can be shipped aleady activated. Note: in **OTAA** AppKey is write only, in reading the field will always be empty, even if set. ==== 5.2 Other settings ==== **Network settings**:\\ please keep "Any" settings. Change it only if Objenious network is used (default_ any). **Network type**:\\ LoRa syncword can be setted as "private"(0x12) instead "public" (0x34), but __the NS must be setted accordingly__ (default: public). **Band**:\\ select the right LoRaWAN (r) band settings accodingly to country requirements. {{ :wiki:manual_mcf-lw12co2e:activation3_0.jpg?400 |}} **DST**:\\ set to change DST (default: none). **No time sync**:\\ set to disable time synchronization request (default: enabled). ----- {{:warning.png?40|}} Normally sensor asks for a time sync at every power on (uplink starting with 01) or, if enabled, once a week. If not handled in the right way can cause a unnecessary battery consumption (battery life < 2 years). Please check chapter 2.1 [[data_frame_format| DATA FRAME FORMAT]]. ----- **UnConfirmed**:\\ set for unconfirmed uplinks (default: confirmed uplink). **Single join/day**:\\ set for to allow only one join per day (default: multiple join allowed). {{ :wiki:manual_mcf-lw12co2e:settings1_0.jpg?400 |}} ===== 6 Passwords===== The device can be protected by passwords, to avoid unauthorized persons to read data or modify parameters. As default passwords are equal to 0. Allowed values range from 0 to 99999999 (only numbers). To change the passwords, set the new values with the LoRa Tool App: {{ :wiki:manual_mcf-lw12co2e:password1_0.jpg?400 |}} Once the passwords are setted, to gain access from LoRa Tool to the sensor, open the App: {{ :wiki:manual_mcf-lw12co2e:nfc_0.jpg?400 |}} and set the right values before reading from the device: {{ :wiki:manual_mcf-lw12co2e:password2_0.jpg?400 |}} To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future (please provide the DevEUI of the sensor when you ask for that code). ===== 7 Configuration file ===== WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in case of multiple devices configuration. With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to Angel4Future's support if needed. {{ :wiki:manual_mcf-lw12co2e:files_rev0.jpg?400 |}} ====7.1 Multi devices configuration ==== WIth LoRa Tool App is possible to configure many devices in an easy way. For multi-configuration is needed at least one XML file with the parameters to set. Settings on this file will be applied to all the sensors. With an additional XLS file is possible to load different LoRa configuration parameters (Activation Type, AppKey, AppEUI, NetKey, DevAddress, Band, Private option) for each sensor, based on DevEUI. When the sensor is approached, if one parameter is different from files, the APP will ask you if you want to overwrite. XLS is prevailing on the XML, so if both files are enabled, if the DevEUI of the device matches one of the DevEUIs in the XLS file, LoRa parameters will be setted from this one. one. These configuration can be done in the in the Settings: * Enable or disable the use of the general configuration by file; * Enable or disable the use of the specific configuration by file; * Verify the passwords; * Writing the passwords. {{ :wiki:manual_mcf-lw12co2e:multiple_rev0.jpg?400 |}} For details on files format please ask to Angel4Future. ===== 8 LoRaWEB Tool ===== Angel4Future provides free **LoRaWEB** online tool, where for each sensor it is possible to find documentation, javascript examples for parsing, downlink generator and uplink decoder: [[https://iot.mcf88.cloud/LoRaWeb/#/configuration|LoRaWEB Tool]] (iot.mcf88.cloud/LoRaWeb) {{ :wiki:manual_mcf-lw12co2e:lt1_0.jpg?600 |}} {{ :wiki:manual_mcf-lw12co2e:lt2_0.jpg?600 |}} ===== 9 Payload ===== For payload descriptions, uplinks and downlinks format and available commands please refer to this document: [[data_frame_format| DATA FRAME FORMAT]] ===== 10 Ordering code ===== ^Code ^Description ^ |MCF-LW12TER | enginko LoRaWAN(r) indoor environmental EU863-870 | |MCF-LW12TER-AS | enginko LoRaWAN(r) indoor environmental sensor AS920-925 | |MCF-LW12TER-US | enginko LoRaWAN(r) indoor environmental sensor US902-928 | |MCF-LW12TER-AU | enginko LoRaWAN(r) indoor environmental sensor AU915-928 | ===== 11 Declaration of conformity ===== Declarations of conformity are available from Angel4Future by sending a request email to sensor@enginko.com. __false__