| Line 10: | Line 10: | ||
| * Do not dismantle or modify in any way. | * Do not dismantle or modify in any way. | ||
| - | * The device is not intended to be used as a reference sensor, and enginko | + | * The device is not intended to be used as a reference sensor, and Angel4Future |
| * Avoid mechanical stress | * Avoid mechanical stress | ||
| * Do not use any detergent or alcohol to clean the device. | * Do not use any detergent or alcohol to clean the device. | ||
| + | * Risk of explosion if the battery is replaced with an incorrect type. | ||
| + | * Risk of explosion if the battery pack is subjected to a short circuit. | ||
| + | * Risk of explosion if the battery is burned or placed near high heat sources. | ||
| + | * Risk of explosion if batteries are crushed, punctured or cut. | ||
| + | * Do not expose batteries to contact with liquid substances. | ||
| === Disposal information for users === | === Disposal information for users === | ||
| Line 21: | Line 26: | ||
| Please note that the lithium batteries must be removed from the equipment before it is given as waste and disposed separately. To remove the batteries refer to the specifications in the user manual. For additional information and how to carry out disposal, please contact the certified disposal service providers. | Please note that the lithium batteries must be removed from the equipment before it is given as waste and disposed separately. To remove the batteries refer to the specifications in the user manual. For additional information and how to carry out disposal, please contact the certified disposal service providers. | ||
| + | |||
| ===== 1. Description ===== | ===== 1. Description ===== | ||
| Line 34: | Line 40: | ||
| * Class A LoRaWAN® 1.0.2 , EU868 | * Class A LoRaWAN® 1.0.2 , EU868 | ||
| * OTAA/ABP activation | * OTAA/ABP activation | ||
| - | * Temperature -40 ÷ 70°C (typ. ±0.48°C within [-30 ÷ 70°C], typ. ±0.60°C otherwise) | + | * Temperature -40 ÷ 65°C (typ. ±0.48°C within [-30 ÷ 65°C], typ. ±0.60°C otherwise) |
| * Humidity 0% to 100% with following error @25°C: | * Humidity 0% to 100% with following error @25°C: | ||
| Line 53: | Line 59: | ||
| * Up to 3000 sets of historical data records | * Up to 3000 sets of historical data records | ||
| * Storage temperature -40°C ÷ +80°C | * Storage temperature -40°C ÷ +80°C | ||
| - | * Working temperature -40°C ÷ +70°C | + | * Working temperature -40°C ÷ +65°C |
| * Dimensions: 65.5×58.5×32.5mm | * Dimensions: 65.5×58.5×32.5mm | ||
| * Protection grade: IP65 | * Protection grade: IP65 | ||
| Line 158: | Line 164: | ||
| This sensor contains lithium battery, which must be disposed of separately. | This sensor contains lithium battery, which must be disposed of separately. | ||
| - | EGK-LW22CCM is provided with two CR123A | + | EGK-LW22CCM is provided with two CR123A batteries. |
| This is the estimated battery life (in **years**) in the worst conditions: | This is the estimated battery life (in **years**) in the worst conditions: | ||
| Line 170: | Line 176: | ||
| * remove the front panel of the sensor with a small hex key (for M2.5 bolts): | * remove the front panel of the sensor with a small hex key (for M2.5 bolts): | ||
| - | {{ : | + | {{ : |
| - | * remove the PCB batteries | + | * remove the PCB batteries from the board and put the new ones: |
| - | {{ : | + | {{ : |
| - | {{ : | + | {{ : |
| * Place the front panel and fix it with the 4 bolts. | * Place the front panel and fix it with the 4 bolts. | ||
| - | |||
| __After the batteries replacement, | __After the batteries replacement, | ||
| Line 185: | Line 190: | ||
| {{ : | {{ : | ||
| - | To perform the operation, you need a unique reset code that must be requested to enginko | + | To perform the operation, you need a unique reset code that must be requested to Angel4Future |
| {{ : | {{ : | ||
| At the end of the procedure the battery level displays 100%. | At the end of the procedure the battery level displays 100%. | ||
| + | |||
| ==== 2.7 Firmware update ==== | ==== 2.7 Firmware update ==== | ||
| Line 276: | Line 282: | ||
| - **NONE**: sensor not activated | - **NONE**: sensor not activated | ||
| - **OTAA**: the JoinEUI and the AppKey not setted, must be written to the device; | - **OTAA**: the JoinEUI and the AppKey not setted, must be written to the device; | ||
| - | - **OTAA | + | - **OTAA |
| - **OTAA ENGINKO**: Over the air activation, fixed keys: JoinEUI = 904e915000000001, | - **OTAA ENGINKO**: Over the air activation, fixed keys: JoinEUI = 904e915000000001, | ||
| - **ABP**: requires writing to the device of NwkSkey, AppSkey, DevAddr. | - **ABP**: requires writing to the device of NwkSkey, AppSkey, DevAddr. | ||
| {{ : | {{ : | ||
| - | The device exits factory activated with **NONE** mode. On request devices can be shipped aleady activated. | + | The device exits factory activated with **OTAA ENGINKO** mode. On request devices can be shipped aleady activated. |
| Note: in **OTAA** | Note: in **OTAA** | ||
| + | |||
| ==== 4.2 Other settings ==== | ==== 4.2 Other settings ==== | ||
| Line 356: | Line 363: | ||
| {{ : | {{ : | ||
| - | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko | + | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future Srl |
| ===== 6 Configuration file ===== | ===== 6 Configuration file ===== | ||
| - | WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in case of multiple devices configuration. | + | WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in case of multiple devices configuration. |
| - | With " | + | With " |
| {{ : | {{ : | ||
| Line 389: | Line 397: | ||
| {{ : | {{ : | ||
| - | For details on files format please ask to enginko. | + | For details on files format please ask to Angel4Future. |
| ===== 7 LoRaWEB Tool ===== | ===== 7 LoRaWEB Tool ===== | ||
| - | enginko | + | Angel4Future |
| [[https:// | [[https:// | ||
| Line 428: | Line 436: | ||
| ===== 11 Declaration of conformity ===== | ===== 11 Declaration of conformity ===== | ||
| - | Hereby, enginko Srl declares that EGK-LW22CCM complies with the essential requirements and other relevant provisions | + | Declarations |
| ===== 12 Contacts ===== | ===== 12 Contacts ===== | ||
| - | **enginko Srl** \\ | + | **Angel4Future S.r.l.** \\ |
| - | Via Roma 3 I-28060 Sozzago | + | Via San Sabino 21 - 70042 MOLA DI BARI (BA) , ITALY \\ |
| - | T : +39 0321 15 93 088 | + | T : +39 080 532 1796 \\ |
| - | E : info@enginko.com\\ | + | E : info@angel4future.com \\ |
| - | PEC: enginkosrl@legalmail.it\\ | + | W: |