manual_egk_lw22twp00 [2024/02/14 09:41] – [2.1 Technical data] supportadminmanual_egk_lw22twp00 [2026/05/20 09:44] (current) – [10 Declaration of conformity] supportadmin
Line 10: Line 10:
  
   * Do not dismantle or modify in any way.   * Do not dismantle or modify in any way.
-  * The device is not intended to be used as a reference sensor, and enginko Srl will not be held liable for any damage which may result from inaccurate readings.+  * The device is not intended to be used as a reference sensor, and Angel4Future  Srl will not be held liable for any damage which may result from inaccurate readings.
   * Avoid mechanical stress   * Avoid mechanical stress
   * Do not use any detergent or alcohol to clean the device.   * Do not use any detergent or alcohol to clean the device.
Line 44: Line 44:
   * Class A LoRaWAN® 1.0.2 , EU868   * Class A LoRaWAN® 1.0.2 , EU868
   * OTAA/ABP activation   * OTAA/ABP activation
-  * Temperature -30 ÷ 65°C (typ. ±0.2°C within [0 ÷ 65°C], typ. ±0.5°C otherwise)+  * Temperature -40 ÷ 65°C (typ. ±0.2°C within [0 ÷ 65°C], typ. ±0.5°C otherwise)
   * Humidity 0% to 100% with following error @25°C:   * Humidity 0% to 100% with following error @25°C:
- - From 0% to 10% ±3%\\ + 
- - From 10% to 90% ±2%\\ +- From 0% to 10% ±3% \\ - From 10% to 90% ±2% \\ - From 90% to 100% ±3%
- - From 90% to 100% ±3%\\+
  
   * Pressure 300….1250hPa (±1hPa)   * Pressure 300….1250hPa (±1hPa)
Line 61: Line 60:
   * BLE 5.0 interface for configuration, data reading and FW upgrade   * BLE 5.0 interface for configuration, data reading and FW upgrade
   * Remote configuration   * Remote configuration
-  * Storage temperature -30°C ÷ +80°C +  * Storage temperature -40°C ÷ +80°C 
-  * Working temperature -30°C ÷ +65°C+  * Working temperature -40°C ÷ +65°C
   * Dimensions: 98×58.5x39mm   * Dimensions: 98×58.5x39mm
   * Protection grade: IP67   * Protection grade: IP67
   * Weight: 95g   * Weight: 95g
 +
  
 ==== 2.2 Installation ==== ==== 2.2 Installation ====
Line 137: Line 137:
 ^Code  ^Description  | ^Code  ^Description  |
 |EGK-1S2PCR  |  4800mAh battery pack  | |EGK-1S2PCR  |  4800mAh battery pack  |
-__Replacement battery only available from enginko.__\\+__Replacement battery only available from Angel4Future .__\\
  
 This is the estimated battery life (in **years**) in the worst conditions: This is the estimated battery life (in **years**) in the worst conditions:
Line 167: Line 167:
 {{  :wiki:manual_mcf-lw12terwp:batt_res.jpg?400  |batt_res.jpg}} {{  :wiki:manual_mcf-lw12terwp:batt_res.jpg?400  |batt_res.jpg}}
  
-To perform the operation, you need a unique reset code that must be requested to enginko (please provide the DevEUI of the sensor when you ask for that code):+To perform the operation, you need a unique reset code that must be requested to Angel4Future  (please provide the DevEUI of the sensor when you ask for that code):
  
 {{  :wiki:manual_mcf-lw12co2e:battery_res_0.jpg?400  |battery_res_0.jpg}} {{  :wiki:manual_mcf-lw12co2e:battery_res_0.jpg?400  |battery_res_0.jpg}}
Line 228: Line 228:
   - **NONE**: sensor not activated   - **NONE**: sensor not activated
   - **OTAA**: the JoinEUI and the AppKey not setted, must be written to the device;   - **OTAA**: the JoinEUI and the AppKey not setted, must be written to the device;
-  - **OTAA ENGINKO**: Over the air activation, fixed keys: JoinEUI = 904e915000000001, AppKey on request;+  - **OTAA MCF88**: Over the air activation, fixed keys: JoinEUI = 904e915000000001, AppKey on request;
   - **OTAA ENGINKO**: Over the air activation, fixed keys: JoinEUI = 904e915000000001, AppKey on request;   - **OTAA ENGINKO**: Over the air activation, fixed keys: JoinEUI = 904e915000000001, AppKey on request;
   - **ABP**: requires writing to the device of NwkSkey, AppSkey, DevAddr.   - **ABP**: requires writing to the device of NwkSkey, AppSkey, DevAddr.
 {{  :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400  |activation1_0.jpg}} {{  :wiki:manual_mcf-lw12co2e:activation1_0.jpg?400  |activation1_0.jpg}}
  
-The device exits factory activated with **NONE**  mode. On request devices can be shipped aleady activated.+The device exits factory activated with **OTAA ENGINKO**  mode. On request devices can be shipped aleady activated.
  
 Note: in **OTAA**  AppKey is write only, in reading the field will always be empty, even if set. Note: in **OTAA**  AppKey is write only, in reading the field will always be empty, even if set.
Line 307: Line 307:
 {{  :wiki:manual_mcf-lw12co2e:password2_0.jpg?400  |password2_0.jpg}} {{  :wiki:manual_mcf-lw12co2e:password2_0.jpg?400  |password2_0.jpg}}
  
-To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko (please provide the DevEUI of the sensor when you ask for that code).+To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future  (please provide the DevEUI of the sensor when you ask for that code).
  
 ===== 6 Configuration file ===== ===== 6 Configuration file =====
  
-WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in case of multiple devices configuration.+WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future ). This is very useful especially in case of multiple devices configuration.
  
-With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to enginko's support if needed.+With "Save" button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to Angel4Future 's support if needed.
  
 {{  :wiki:manual_mcf-lw12co2e:files_rev0.jpg?400  |files_rev0.jpg}} {{  :wiki:manual_mcf-lw12co2e:files_rev0.jpg?400  |files_rev0.jpg}}
Line 340: Line 340:
 {{  :wiki:manual_mcf-lw12co2e:multiple_rev0.jpg?400  |multiple_rev0.jpg}} {{  :wiki:manual_mcf-lw12co2e:multiple_rev0.jpg?400  |multiple_rev0.jpg}}
  
-For details on files format please ask to enginko.+For details on files format please ask to Angel4Future .
  
 ===== 7 LoRaWEB Tool ===== ===== 7 LoRaWEB Tool =====
  
-enginko provides, upon free registration, **LoRaWEB**  online tool, where for each sensor it is possible to find documentation, javascript examples for parsing, downlink generator and uplink decoder:+Angel4Future  provides  free  **LoRaWEB**  online tool, where for each sensor it is possible to find documentation, javascript examples for parsing, downlink generator and uplink decoder:
  
 [[https://iot.ENGINKO.cloud/LoRaWeb/#/configuration|LoRaWEB Tool]] (iot.ENGINKO.cloud/LoRaWeb) [[https://iot.ENGINKO.cloud/LoRaWeb/#/configuration|LoRaWEB Tool]] (iot.ENGINKO.cloud/LoRaWeb)
Line 366: Line 366:
 ===== 10 Declaration of conformity ===== ===== 10 Declaration of conformity =====
  
-Hereby, enginko Srl declares that EGK-LW22TWP00 complies with the essential requirements and other relevant provisions of Directive 2014/53/EU.+Declarations of conformity are available from Angel4Future by sending a request email to sensors@enginko.com.
  
  
 ===== 11 Contacts ===== ===== 11 Contacts =====
  
-**enginko Srl** \\ Via Roma 3 I-28060 Sozzago (NO) \\ T : +39 0321 15 93 088+**Angel4Future S.r.l.** \\  
 +Via San Sabino 21 70042 MOLA DI BARI (BA, ITALY \\  
 +    +39 080 532 1796 \\  
  
-E : info@enginko.com \\ PEC: enginkosrl@legalmail.it \\ W: enginko.com+    info@angel4future.com  \\  
 +W:     enginko.com \\ 
  
 ---- ----